À propos
Greasy Wheels is a Service Company based in SouthEast Massachusetts that specializes in Commercial Appliance Repair and HVAC and Residential work also.
Toutes les évaluations (24)
- alaben-80 (96)- Évaluation laissée par l'acheteur.Il y a plus d'un anAchat vérifiéGood clients
- nutmegsupply (571)- Évaluation laissée par l'acheteur.Il y a plus d'un anAchat vérifiéGreat ebayer, pleasure to do business with! Thanks!
- *****- Évaluation laissée par l'acheteur.Il y a plus d'un anAchat vérifiéThank you for your purchase!!
- commercialkitchendirect (25374)- Évaluation laissée par l'acheteur.Il y a plus d'un anAchat vérifiéGreat Commercial Kitchen Direct buyer, easy transaction! Recommended!
- kenhin5359 (923)- Évaluation laissée par l'acheteur.Il y a plus d'un anAchat vérifiéQuick response and fast payment. Perfect! THANKS!!
- betstev-54 (280)- Évaluation laissée par l'acheteur.Il y a plus d'un anAchat vérifiéQuick response and fast payment. Perfect! THANKS!!
Avis (12)

28 mai 2017
Quite happy with these.
A little different than many compressors, the suction connection is on the opposite side from many other brands. No big deal to add a short length of copper to get it to where it needs to be, or in one case, cutting a little off. Also, the mount is different from many others, but again, a little change to that is of no consequence. Quiet running, I can say that I'd recommend these, as a matter of fact, I just ordered 4 more of various sizes! Good Value.
NEW TIF SPX Model 3310 Professional Differential Thermometer Tester NIB HVAC
04 avr. 2017
TIF 'anything', guages, scales, etc are another of the Gold Standard items that so many techs want. 2 inputs make calculating differential EASY!

28 janv. 2018
The exact replacement...
1 personnes sur 1 ont jugé cet avis utile. This item requires specialized understanding of small capacity refrigeration systems. Embraco is the actual manufacturer and they are among the most reliable in the industry. I have installed hundreds and not one has ever given me any trouble. You absolutely must perform an acid test and remediate as required if present. You must be able to braze, not solder the connections. If you use common plumber's flux, you'll destroy the system. You must replace the filter-drier. You MUST vacuum the system with a proper vacuum pump to the correct vacuum levels. Then, and only then should you charge the system with exactly the amount the nameplate says it should. Any deviation from this will result in a non or poorly operating system. I can't even begin to estimate the number of small units that I have come across that were extremely overcharged, soldered, or otherwise incorrectly installed. That wouldn't be the 'part's fault'!